International Crystal Laboratories has quartz & special IR, NIR, UV, & VIS cuvettes for any spectroscopy application.
ICL’s cells and cuvettes meet the most exacting requirements of modern spectrophotometric procedures. All spectrophotometer cells are completely fused without the use of low melting intermediate glasses or cements. In other words, quartz is fused to quartz and glass is fused to glass. This eliminates strains due to differences in coefficients of expansion found in cells fused with intermediate low melting temperature glasses. Because of the fused construction, the window joints of ICL spectrophotometer cells are unaffected by all types of cleaning solutions.
Standard Spectrophotometer Cell
TYPE 1
Cell with fitted cover. Satin finish on two sides.
Lightpaths: 1, 2, 5, 10, 20, 40, 50 and 100 mm.
Outside dimensions: 45 mm high, 12.5 mm wide.
Cylindrical Spectrophotometer Cell Hydrocarbon Analysis
TYPE 34
Cylindrical cell with two stoppers.
Lightpaths: 50 and 100 mm.
Outside diameter: 22 mm.
Use IR Grade for hydrocarbon analysis.
Standard Spectrophotometer Cell Screw Cap
TYPE 1 SC
Same as Type 1 but with screw caps.
Lightpath: 10mm only.
Cylindrical Spectrophotometer Cell Hydrocarbon Analysis
TYPE 32
Cylindrical cell with one stopper.
Lightpaths: 2, 5, 10 and 20mm.
Outside diameter: 22 mm.
Use IR Grade for hydrocarbon analysis.
Cylindrical Cell Screw Cap
TYPE 34 SC
Cylindrical cell with screw caps.
Lightpaths: 50 and 100 mm.
Outside diameter: 22 mm.
Use IR Grade for hydrocarbon analysis.
Standard Spectrophotometer Cell Graded Seal
TYPE 1 GS
Same as type 1 but with graded seal 8mm tube OD, 120mm height.
Lightpath: 10mm only.
Fluorimeter Cell Graded Seal
TYPE 3 GS
Same as type 3 but with graded seal 8mm tube OD, 120mm height.
Lightpath: 10mm only.
Cylindrical Cell Hydrocarbon Analysis
TYPE 37
Long neck cylindrical cell.
Lightpaths: 1,2, and 5mm.
Outside Diameter: 22mm.
Standard Fluorimeter Cell
TYPE 3
Cell with fitted cover for fluorimetry. All 4 sides and bottom polished.
Lightpaths: 2, 5, 10, 20, 40 and 50 mm.
Outside dimensions: 45 mm high x 12.5 mm wide.
Semi-Micro Fluorimeter Cell
TYPE 29F
Semi-Micro Cell. Same as Type 9F except with tapered PTFE
stopper
Semi-Micro Cell
TYPE 9
Semi-micro cell with fitted cover. Satin finish on two sides. Inside width 4mm.
Lightpaths: 5, 10, 20 and 40 mm.
Outside Dimensions:
45 mm high x 12.5 mm wide.
Fluorimeter Cell
TYPE 30F
Cell with PTFE stopper. Same as Type 30 but with 4 clear windows and clear bottom.
Fluorimeter Cell
TYPE 9F
Semi-micro cell with fitted cover. Same as Type 9 but with 4 clear windows and clear bottom.
Lightpath: 10mm only.
Outside Dimensions:
45 mm high x 12.5 mm wide.
Micro Cell PTFE Stopper
TYPE 30
Micro Cell with tapered PTFE stopper. Satin finish on two sides.
Lightpaths: 5, 10, 20, 30, 40, 50mm.
Outside Dimensions: 45 mm high x 12.5 mm wide.
Semi-Micro Cell
TYPE 17
Micro Cell with fitted cover.
Inside width: 2 mm.
Lightpaths: 5, 10, 20 and 40 mm.
Outside Dimensions: 25 mm high x 12.5 mm wide
Fluorimeter Cell
TYPE 18F
Micro volume cell with fitted PTFE cover, 4 clear windows and clear bottom.
Lightpath: 10mm only.
Outside Dimensions: 45mm high x 12.5mm wide.
Split Cell
TYPE 22
Split cell with fitted cover. 4 sides polished.
Lightpaths: Two sections in parallel 10 mm or two sections in series 4.5 mm.
Outside dimensions:
45 mm high x 12.5 mm wide.
Micro Cell
TYPE 18
Micro volume cell with fitted PTFE Cover. Satin finish on 4 sides.
Lightpaths:10mm only.
Outside Dimensions: 45 mm high x 12.5 mm wide.
Black Masked Micro Cell
TYPE 18 BM
Micro cell with fitted PTFE cover self-masking black quartz.
Lightpath: 10mm only.
Outside Dimensions: 45 mm high x 12.5 mm wide
Black Masked Semi-Micro Cell
TYPE 17BM
Micro Cell with PTFE cover.
Same as Type 17 in self-masking black quartz.
Lightpaths: 10, 20, 40 mm.
Ultra Micro Flow Cell
TYPE 75BM
Continuous flow-through ultra-micro. Two windows polished. Internal width of sample chamber: 3 mm diameter.
Lightpath: 10mm only.
Outside Dimensions: 45mm high x 12.5mm wide.
Flow Cell
TYPE 42
Flow cells with flow tubes.
Lightpaths: 10 mm only.
Outside heights: Without tubes 45 mm. With tubes approx. 65 mm.
Outside width: 12.5 mm.
Black Masked Flow Cell
TYPE 42BM
Flow through semi-micro cell self-masking black quartz.
Lightpath: 10mm only.
Outside Height: 45mm, with tubes approx. 65mm.
Outside Width: 12.5mm.
Divided Cell
TYPE 26
Divided pathlength cell with fitted cover.
Lightpaths: 2 mm x 10 mm.
Outside dimensions: 45 mm high x 12.5 mm wide.
Black Masked Semi-Micro Cell
TYPE 9BM
Semi-Micro cell with PTFE Cover. Same as Type 9 in self-masking black quartz.
Lightpath: 10mm only.
Black Masked Semi-Micro Cell
TYPE 29BM
Semi-Micro Cell same as Type 9 but with PTFE stopper.
Lightpath: 10mm only.
Outside Dimensions: 45mm high x 12.5mm wide.
Black Masked Micro Cell
TYPE 30 BM
Micro cell same as Type 18 but with PTFE stopper.
Lightpath: 10mm only.
Outside Dimensions: 45 mm high x 12.5 mm wide.
Black Masked Micro Cell
BM Micro Cell
Micro Cell with PTFE stopper. Black masked over the whole pathlength.
Pathlengths: 1, 5 and 10mm
Outside Dimensions: 12.5 mm wide x 19mm high
Demountable Cell
TYPE 20C
Demountable cell.
Pathlengths: 0.1, 0.5 and 1mm.
Outside Dimensions: 12.5mm wide x 45mm long/high.
Flow Through Demountable Cell
TYPE 49
Flow through demountable cell with hose barbs.
Pathlengths: 0.5, 1mm.
Outside Dimensions: 12.5mm wide x 45mm long/high.
Comparator Cell
TYPE 70
Cell for Comparator.
Lightpaths: 1, 5, 10, 20 and 40 mm.
Outside Dimensions: 60 mm high x 20 mm wide.
Absorptiometer Cell
TYPE 60
Made of optical glass.
Cell for Absorptiometer.
Lightpaths: 5, 10, 20, 40, 100 mm.
Outside Dimensions: 40 mm x 28 mm wide.
Water Jacketed Cell
TYPE 24
Jacketed cell for heating or cooling. Sample section 4 mm wide.
Lightpath: 10 mm.
Outside dimensions: 45 mm high x 12.5 mm wide.
Tintometer Cell
TYPE 80
Cell for Tintometer.
Lightpath: 5, 10, 20 and 40mm.
Outside Dimension: 40mm high x 18mm wide.