Polystyrene Calibration Films
Radially Symmetric Polystyrene Calibration Films & Calibration Films Cast On KBr Windows
( U.S. Patent No. 6,254,931– Other Patents Pending)
Boron Doped KBr Calibration Windows
(U.S. Patent No. 6,594,008)
PhEur 2.2.24 Calibration Standards

In addition to standard polystyrene calibration films, ICL offers several other calibration options. Superior calibrations are performed with radially symmetric films which eliminate the orientation effects of extruded films used for NIST Standard 1921 calibrations. This makes the films consistent from film to film. Sold in pairs of two (2) different film thickness, the differential between the absorbance intensities created by the two (2) film thickness becomes the baseline, thereby making the pair of films suitable both as an ordinate calibration standard useful for detection of degradation in instrument performance and for calibrating the abscissa scale in accordance with NIST Standard 1921. Films are available in free standing pairs mounted on 2” x 4” cards that fit in the standard universal slide mount in all spectrophotometers or the films can be cast on KBr windows. Films cast on KBr windows will not exhibit any interference fringes. KBrwindows with films are sold with a mount with a 2” x 3” backplate that fits the standard universal slide mount in all spectrophotometers.

The polystyrene coating prevents degradation of the KBr window from moisture effects. Boron doped crystal windows are also available as calibration standards. These windows can be matched in pairs with comparable absorbances.

Polystyrene Calibration Films Product Options

 

Part No.DescriptionPrice
0009-2500Polystyrene Test Film – 38 microns thick$40.00
0009-8181Polystyrene Test Film – 76 microns thick$118.00
0009-8182Pair of polystyrene calibration films of different thickness. One film is 38 microns and is provided with certification of traceability to five (5) NIST 1921b frequencies. The second film is 76 microns and is provided without certification. Both films are mounted on 2″ x 3″ cardstock holder with a 19mm aperture for mounting in the universal slide holder in all instruments. Includes instructions for two (2) film ordinate calibration and storage case. Also available with PhEur 2.2.24 certified polystyrene calibration film (inquire for quote).$267.00
0009-8487Same as 0009-8182, but with PhEur 2.2.24 certified films.$266.20
0009-7676NIST traceable Polystyrene Test film, certificate of traceability to five (5) NIST 1921b frequencies, set of 2 films each mounted to 2” x 4” cardstock holder$261.00
0009-7393Pair of polystyrene films of different thickness, both with NIST traceability certification. Kit also includes a pair of standard polystyrene films, but without NIST traceability certification. One NIST traceable film is mounted on 2″ x 4″ cardstock, which enables mounting in the standard universal slide mount found in all spectrophotometers, and is the same thickness as an NIST 1921 standard film (38 microns). The second thinner NIST traceable film is cast on KBr and includes holder and mounting device. Kit includes certification of traceability to five (5) NIST 1921b frequencies, radial symmetry certification for film cast on KBr and storage cases for all films.$366.00
0009-7394Pair of polystyrene calibration films of different thickness cast on KBr, radial symmetry certification, summary of NIST standard 1921 with frequency locations, certification of traceability to five (5) NIST 1921b frequencies, instructions for two (2) film ordinate calibration, slide mount holder. Kit also includes a pair of standard polystyrene films, without NIST traceability certification, mounted on 2″ x 4″ cardstock which enables mounting in the standard universal slide mount found in all spectrophotometers. Storage case provided.$593.00
0009-9247Pair of 13mm x 2mm KBr windows intended to fit FTIR microscope stage, coated with polystyrene and certified to five (5) NIST 1921b frequencies$299.00
0009-7395Single Boron doped KBr Crystal calibration standard with slide mount holder and storage case. (U.S. Patent No. 6,594,008)RFQ
0009-7396Pair of matched Boron doped KBr windows.
(U.S. Patent No. 6,594,008)
RFQ
0009-8157Polystyrene calibration film for PhEur 2.2.24 calibration of IR and FTIR instruments, certified to 7 wave-numbers and certified as to absorption minima and maxima differentials at 2870 cm-1 and 2849.5cm-1 and at 1589 cm-1 and 1583 cm-1$181.00
0009-8158Pair of PhEur 2.2.24 certified polystyrene calibration films, same as 0009-8157 but with 2 certified films$278.00
0009-8559Polystyrene Calibration film for PhJap 2.25 calibration of IR and FTIR instruments, certified to 7 wave numbers, mounted on 2″ x 4″ card stock$161.00
0009-8558Pair of PhJap 2.25 certified polystyrene calibration films, same as 0009-8559 but with 2 certified Films$245.00
0009-8560Polystyrene calibration film, certificate of traceability to seven (7) NIST frequencies (wave numbers) and certified as to absorption minima and maxima differentials at 2870cm-1 and 2849.5cm-1 and 1589cm-1 and 1583cm-1 as required by PhEur 2.2.24$211..00
0009-8448Polystyrene calibration film, certificate of traceability to seven (7) NIST frequencies (wave numbers) and certified as to absorption minima and maxima differentials at 2870cm-1 and 2849.5cm-1 and 1589cm-1 and 1583cm-1 as required by PhEur 2.2.24 and also certified to PhJap 2.25$251.60
0009-8437Pair of films same as 0009-8448$361.00
0009-9248Custom Cut Polystyrene film cut to the size of any Horizontal ATR accessory (please specify, up to 4″ square), certified to five (5) NIST 1921b frequencies$182.00