ICLs
Basics Horizontal ATR is a high performance accessory
that is easy on your lab budget. In its standard configuration
the sample is placed into a large trough sample area that
can be used for analysis of liquids, pastes, films and powders.
Sample preparation is minimal. You simply place your sample
into the easily removable top plate so that it sits in the
trough above the ATR crystal. An 80x10x4mm ZnSe crystal
is standard, but Ge is available as an option.
An
optional flat top plate configuration is available if you
intend to sample a lot of powders and films. The flat top
plate enhances the contact between the surface of the ATR
crystal and the sample when used in conjunction with the
optional clamp that allows you to apply pressure to the
sample. A powder press is also available to fit the trough
top plate configuration for powder sampling.
In
designing the Basics Horizontal ATR we have eliminated
some of the problems associated with earlier designs in
which the ATR crystal prism is held in place with epoxy.
In both the trough and the flat plate configuration the
optics of the Basics Horizontal ATR are held in place
mechanically, or with an indium seal. This accessory also
features Constant Purge, which allows sampling without
breaking the nitrogen or dry air purge of your spectrophotometer.
We have also introduced heated and micro flow-through top
plates for this accessory. For flow through applications,
see Precision Dispenser pump.
When
ordering, please specify the make and model of your spectrophotometer.
| Part
No. |
Description |
| 0015-4713 |
Basics
Horizontal ATR, trough plate with ZnSe ATR crystal prism |
| 0015-4714 |
Basics
Horizontal ATR, flat top plate with ZnSe ATR crystal
prism with clamp assembly |
| 0015-7687 |
Recognition
System add-on for any spectrophotometer |
| 0015-4715 |
Trough
top plate with ZnSe ATR prism |
| 0015-4716 |
Flat
top plate with ZnSe ATR prism |
| 0015-4717 |
Powder
Press for Trough Top Plate |
| 0015-4718 |
Clamp
for Flat Top Plate |
| 0015-4719 |
Volatiles
Cover |
| 0003J-6092 |
ZnSe
Replacement ATR Crystal |
| 0015-5023 |
Heated
ZnSe Trough Top Plate to 100°C with two type T Copper-
Constantan thermocouples, one for sample and one for
heater. |
| 0015-5096 |
Heated
trough top plate package: includes top plate heatable
to 100°C, ZnSe prism, temperature controller (0017-5548)
with digital display. Controller regulates temperature
of top plate and readouts show set point and temperature
of sample. Does not include 0015-4713 |
| 0015-5024 |
110
microliter Flow-Through top plate |
| 0015-5343 |
550
microliter Flow-Through top plate |
| 0015-5098 |
RS-232
or RS-485 communications interface for use of controller
with personal computer. |
|