ICLs
new low cost, high quality graphite tubes meet or exceed
OEM specifications for graphite replacement tubes to be
used in their AA spectrophotometers. SAVE OVER 30% OFF OF
OEM PRICES. ICLs graphite tubes are made from ultra
pure grade graphite using the most advanced CVD (chemical
vapor deposition) technology for pyrolytic coating. ICL
tubes have a long analytical life and their sensitivity
exceeds OEM specifications, often with reduced interference
and always at a lower cost. Built-in Lvov platforms
are available for Perkin-Elmer AA spectrophotometers and
those brands using compatible tubes.
CVD pyrolytic coating has two distinct advantages over uncoated
graphite. The coating improves sensitivity by reducing the
porosity of the graphite and it results in longer tube life
at elevated temperatures.
We tested the sensitivity and precision of these tubes using
2 different tubes for over 700 firings with a vanadium standard
[50mg/L (ppb) in 0.2% nitric acid]. Injection volume was
20mL. Analysis was at 318.4 nm with a slit width of 0.7
nm. Sensitivity and precision were calculated every 20 firings.
The sensitivity for vanadium (defined as the concentration
of sample that will produce 0.0044 absorbance units) was
calculated at 0.2mg/L (ppb), which compares to 0.4mg/L quoted
by Thermo Jarrell Ash and 0.8mg/L by Perkin-Elmer. As a
standard of precision we used the relative standard deviation
(RSD), which was near 2% (mostly below) over the 700 firings.
At the end of 700 firings neither of these tubes had reached
the end of its useful life. Absorbance actually increased
after 50 firings and then stayed about the same.
Lvov platforms are used to isolate the sample from
the wall of the tube, which allows more reproducible atomization
of the sample. When the sample is kept from direct contact
with the tube wall, the isolated sample vaporizes into a
higher temperature atmosphere because of the indirect heating.
This produces more free atoms which reduces interferences.
In addition, indirect heating limits sample contamination
of the tube caused by contact with the tube wall. ICL has
a unique Lvov platform available for its PE style
tubes that is built-in and does not require user insertion
of the platform into the tube.
User inserted Lvov platforms are available for GBC
Spectrophotometers. Ask about the availability of Lvov
platforms for other brands.
Why not try the only test that really matters? Take advantage
of our trial offer for new customers and buy just one (1)
tube at same unit price normally available only for quantities
of 10 and try it out in your lab. See for yourself how ICLs
high purity graphite tubes can enhance your results at reasonable
cost.
| Part
No. |
Description |
| 0024-5116 |
Trial
Offer without Lvov Platform |
| 0024-5117 |
Trial
Offer w/ Lvov Platform |
|
0024-5118
0024-5119 |
Pyrolytic
Coated Graphite Tube for PE AA Spectrophotometer furnace,
Without Lvov platform. Fits HGA 2100, 2200, 76B,
300, 400, 500, 600, 700, 800. Also, Buck Scientific,
and ICP/MS furnaces of PE and VG/Fisons. |
|
0024-5120
0024-5121 |
Pyrolytic
coated graphite tube for PE AA Spectrophotometer furnace,
With Built-In Lvov platform. Fits HGA 2100, 2200,
76B, 300, 400, 500, 600, 700. Also, Buck Scientific,
and ICP/MS furnaces of PE and VG/Fisons. |
|
0024-5122
0024-5123 |
Pyrolytic
coated graphite tube for Varian AA Spectrophotometer
furnace, without Lvov platform. Fits Varian GTA
95 and 96. |
|
0024-5126
0024-5127 |
Pyrolytic
coated graphite tube for GBC AA Spectrophotometer furnace.
All models, without Lvov. |
|
0024-5128
0024-5129 |
Pyrolytic
coated graphite tube for GBC AA Spectrophotometer furnace.All
models, with Lvov platform to be inserted by user. |
|